400A Lithium-Ion Battery

Product Specifications

  • Model Number: UPL-12400F
  • Battery Type: LiFePO4
  • Nominal Voltage: 12.8V
  • Nominal Capacity: 400Ah
  • Internal Impedance: < or equal 10m(ohm symbol)
  • Nominal Charge Voltage: 14.6+ (or minus) 0.05V
  • Discharge Cut-off Voltage: 9.2 + (or minus) 0.05V
  • Max. Charge Current: 250 amps
  • Max. Continue Discharge Current: 400 amps
  • Max Pulse Discharge Current: 800 amps (2 sec.)
  • Charge Method: CC (constant charge) | CV (constant voltage)
  • Cycle Life: After 2,000 cycles, capacity > 80% nominal capacity
  • Weight:  132 lbs. (60kg.)
  • Size (L*W*H): 19.25″ x 15″ x 10.25″ (489 x 381 x 260 mm)

Operating Temperatures

  • Operating Temperature Charge: 4-140F (0-20-60 C)
  • Operating Temperature Discharge: 4  – 140  F (0-20-60  C)
  • Storage Temperature: 41-95F (5-35 C)
  • Relative Humidity: 65% +(or minus) 20%

Product Features

Unit Details

  • Cycle Life
  • Temperature: 77-86  F(25-30 C); Charge, 1C CC to 14.6V, and CV to 200mA cut off; Discharge, 1C DC discharge to 9.2V, 80% or more of 1st cycle capacity at 1C discharge of operation, cycles quantity must not less than 2,000 cycles.
  • Remarks: Rest 10 min. after charge and discharge
  • Standard Charge: Charging the cell initially with constant current at 1C and then with constant voltage at 14.6V (accuracy +(or minus) 0.05V) until charging current declines to 0.02C at 77-86  F(25-30C)
  • Standard Discharge: Discharging the cell with constant current at 1C till cut-off voltage at 9.2V. Temperature: 77-86  F (25-30C)
  • Initial Internal Impedance: This means AC impedance of the pack measured at 1 KHz after half fully charged. Initial Internal Impedance < (or equal)20m(ohm)
  •  Initial Capacity: The capacity means the discharge capacity of the battery, which is measured with discharge current of 1C with 9.2V cut-off voltage after the standard charge.
  • Initial Capacity: @95% normal capacity. Temperature: 7 -86  F(25-30  C).
  • Charge Choice
    • Standard charger: 14.6V/250A
    • Charging mode: CC/CV
    • CC: charging current <(or equal) 250A
    • CV: constant voltage 14.6V
    • Charging cut off condition <(or equal) 200mA
Contact Us